EPTC-M AC/DC Hipot Test Set (Manual Control Mode)
General Information:
EPTC-M Series AC/DC Hipot Test Set is suitable for hipot dielectric withstand test on various power electric products, units, insulating material and etc.
Features:
10kVAor above Table type
50kVAor above Cabinet type.
√ Full protection functions
√ Easy to use
√ Long life services
√ Support OEM
Specifications:
Main parameters of EPTC-M Control Unit:

More details on EPTC Series please contact EP Hipot Electric, we have professional tech team to design correctly designed products and systems.



General Information:
EPTC-M Series AC/DC Hipot Test Set is suitable for hipot dielectric withstand test on various power electric products, units, insulating material and etc.
Features:
- Manual controlling.
- Oil-immersed, dry, SF6 gas type transformer is seletable according to user's requirements.
- High anti interference ability.
- High voltage (HV) voltage, Low voltage (LV) current, time, three channels testing ways.
- Real time monitoring HV voltage, LV current.
- Full protection functions: over-current, zero-starting sound light alarm, power switch protection.
- New type time rely, wider time range (1S ~ 99H).
- New type current rely, more precise, more reliable.
- 5kVA and above Testing Transformer with movable iron wheel. Light weight, small size, easy to move, superior performance.
- Display can be designed as needle or digital meter.
- The control tester can be designed to box type, table type, or cabinet type according to user's testing capacity:
10kVAor above Table type
50kVAor above Cabinet type.
√ Full protection functions
√ Easy to use
√ Long life services
√ Support OEM
Specifications:
- Input voltage: AC 220(380)V (customized)
- LV output: AC 0-250(430)V
- LV current: 0-5/10/15/50A (customized)
- Output capacity: 0-3/5/10/15 kVA (customized)
- HV output: 0-50/100/150/200 kV (customized)
- HV current: 0-50/100/150/200/500/1000/2000mA (customized)
- Timing range: 0-9999S
- Working temperature: -20ºC to 50ºC
- Voltage precision: ≤1.5% ±1 digit (F.S)
- Current precision: ≤1.5% ±1digit (F.S)
Main parameters of EPTC-M Control Unit:
Model | Input Voltage (V) | Capacity (KVA) | Rated Output | HV voltmeter KV/V | Oversize m3(L×W×H) | |
Voltage(v) | Current(A) | |||||
EPTC-M05 | 220 | 0.5 | 200 | 2.5 | 50/100 | 20×30×20 |
EPTC-M15 | 220 | 1.5 | 200 | 7.5 | 50/100 | 26×36×24 |
EPTC-M3 | 220 | 3 | 200 | 15 | 50/100 | 26×42×24 |
EPTC-M5 | 220 | 5 | 200 | 25 | 50/100 | 60×45×37 |
EPTC-M6 | 220 | 6 | 200 | 30 | 50/100 | 53×40×60 |
EPTC-M10 | 220 | 10 | 200 | 50/25 | (50/100)/100 | 53×40×65 |
EPTC-M15 | 380 | 15 | 400 | 37.5 | (50/100/150)/100 | 53×40×70 |
EPTC-M20 | 380 | 20 | 400 | 50 | (50/100/150)/100 | 53×43×84 |
EPTC-M25 | 380 | 25 | 400 | 62.5 | (50/100/150)/100 | 53×45×90 |
EPTC-M30 | 380 | 30 | 400 | 67.5 | (50/100/150)/100 | 65×55×115 |
EPTC-M40 | 380 | 40 | 400 | 100 | (50/100/150)/100 | 70×60×115 |
EPTC-M50 | 380 | 50 | 400 | 125 | (50/100/150)/100 | 70×60×115 |

More details on EPTC Series please contact EP Hipot Electric, we have professional tech team to design correctly designed products and systems.